
CIBSE Guide A fresh air rates
CIBSE Guide A fresh air rates for offices and meeting rooms
An office fit-out adds six meeting-room seats. Work through the revised fresh air schedule and see which figures belong in the design handover.
Read the guideEngineering guides and software buyer comparisons for loads, duct sizing, plumbing and hydronics—written for engineers who want to review the method and choose the right workflow.
Showing 46 of 46 guides

CIBSE Guide A fresh air rates
An office fit-out adds six meeting-room seats. Work through the revised fresh air schedule and see which figures belong in the design handover.
Read the guide
CIBSE Guide B2 ventilation rates
Two designers can enter the same headcount and get different results. A 24-person room shows exactly what changes when the specified indoor air quality category changes.
Read the guide
ventilation heat loss calculation fresh air
A boardroom grows from 12 to 18 seats. Calculate the winter heating duty, apply heat recovery and decide which part of the system carries the load.
Read the guide
pump cavitation NPSH hydronic systems
A pump can meet its flow and head duty yet have an unsuitable inlet condition. Separate circulation head from absolute suction pressure, temperature and the manufacturer’s NPSH requirement.
Read the guide
AHU condensate drain trap sizing
A trap can satisfy a pressure calculation and still fail to fit below the air handler. Connect the pan pressure, approved trap detail and downstream drain elevations before installation.
Read the guide
HVAC fan selection
Carry the duct pressure budget into a fan selection you can explain. Check the operating point, filter condition, installation geometry and power before choosing a model.
Read the guide
plate heat exchanger sizing
A 60 kW label does not define a heat exchanger. Build a selection brief that checks both water circuits, the temperature gap between them and the pressure each pump can afford.
Read the guide
hydraulic separation primary secondary flow
Separate the pumps without losing track of the heat. See why a 45°C source can supply only 41.7°C water to the load when circuit flows differ.
Read the guide
radiator sizing for low temperature heating
A radiator’s catalogue rating is not its output at every water temperature. Check the rating basis, room load and manufacturer correction before selecting an emitter.
Read the guide
CIBSE guides for HVAC design
Match the reference to the decision, keep its edition and limitations visible, and pass the right heat duty from the room calculation to each item of equipment.
Read the guide
direct return vs reverse return hydronic piping
Trace the return path, compare circuit pressure losses and see why a more even pipe layout does not automatically mean equal flow or a smaller pump.
Read the guide
Heat → airflow → inlet checks
A cooling unit can have enough capacity while a rack still runs hot. Follow the heat, separate useful airflow from bypass, and check temperatures where the equipment takes in air.
Read the guide
Scope → quantity → cost
A route change affects more than pipe length. Follow a small hydronic package from measured quantities to material and labor costs, then see exactly what changes when the route grows.
Read the guide
Heat loss → floor output → loops
A tidy pipe layout does not prove that a floor can heat the room. Check its usable area and heat output first, then connect spacing, circuit length, flow and pressure loss.
Read the guide
Sections · networks · pressure
Go beyond an isolated duct diameter. MEPFlow brings supply and return layouts, airflow, sizing and pressure-path review into a browser workspace—so the calculation stays close to the ductwork.
Read the guide
Compare plumbing design software for water-supply calculations, automatic pipe sizing, sanitary drainage, 3D layouts and BIM delivery.
Read the guide
Room peaks · systems · energy
Make the floor plan part of the load calculation. MEPFlow combines room geometry, RTS design-day cooling, heating loads and reviewable results in a browser workflow you can try free for 7 days, then $49 USD/month.
Read the guide
Loads · air · water · BIM
Bring room loads, duct layouts and hydronic sizing into a browser platform built for mechanical design. Start with MEPFlow, then choose specialist tools for the BIM and simulation deliverables you need.
Read the guide
Which tools belong in your engineering workflow? Compare 10 options for system calculations, HVAC and plumbing design, BIM coordination and building performance.
Read the guide
Inputs · revisions · review
When every revision means updating a drawing and several calculation files, MEPFlow gives the work a connected home. See how to move recurring duct, pipe and load tasks into the browser.
Read the guide
sanitary drain pipe sizing Canada
One fixture schedule, three different pipe checks. Follow the load from the washroom branch to the stack and building drain, with the governing limits shown at each step.
Read the guide
CFM calculation formula
A room can need 110 CFM of outdoor air and 741 CFM of cooling supply air at the same time. Learn which airflow you are calculating before you select a duct or fan.
Read the guide
heat pump sizing Canada
Choose from building load and equipment performance at the same outdoor temperature. A nominal tonnage or floor-area rule cannot show whether a heat pump covers the coldest design condition.
Read the guide
HRV ERV sizing Canada
An HRV labelled 150 CFM may not deliver 150 CFM through your installed ductwork. Check the required airflow, both pressure paths and the winter operating sequence together.
Read the guide
louver sizing calculation
A practical workflow that separates gross face area from free area and carries a louver estimate through airflow, pressure-drop and rain-performance checks.
Read the guide
pump affinity laws
A practical engineering guide to scaling a centrifugal pump curve, checking the system curve and avoiding common variable-speed hydronic design errors.
Read the guide
CFM ↔ size ↔ velocity ↔ friction
A ductulator gives a fast first size, but the correct result still depends on airflow, friction, velocity, fittings and the complete fan-pressure path.
Read the guide
V = πD²L ÷ 4
Pipe volume is simple geometry, but using nominal instead of actual inside diameter can distort expansion-tank, glycol and fill-volume calculations.
Read the guide
H = pipe + fittings + devices
Pump head is the pressure loss around the controlling closed-loop circuit—not the building height and not one representative pipe-friction value.
Read the guide
Q = U × A × ΔT
Build a transparent winter heat-loss calculation from envelope surfaces, outdoor air and room conditions instead of relying on a single rule of thumb.
Read the guide
Sensible + latent + solar
Separate the gains that change temperature from those that add moisture, then determine when each room and the whole building actually peak.
Read the guide
COP = Qout ÷ Win
A high catalogue COP does not guarantee winter capacity. Read performance at the actual outdoor design temperature and plan supplemental heat deliberately.
Read the guide
V = CFM ÷ A
Use airflow and free area to calculate FPM or m/s, then understand why an acceptable velocity still does not prove the duct system is properly sized.
Read the guide
ΔP = duct + fittings + devices
The longest duct route is not automatically the worst route. Add every straight, fitting and component loss along each complete fan-to-terminal path.
Read the guide
ACH = 60 × CFM ÷ volume
ACH is a useful room-volume relationship, but ventilation, exhaust and pressurization requirements still depend on the governing standard and space use.
Read the guide
Empirical ↔ universal
Follow both methods through the same 30-metre pipe, then see why a small inside-diameter error can matter more than the difference between the equations.
Read the guide
Pstatic → Presidual
A strong static reading does not prove the remote fixture will have enough pressure when the building is flowing at design demand.
Read the guide
Heat loss → flow → head
Recirculation flow replaces distribution heat loss; it is not the same as peak fixture demand or the building's domestic hot-water load.
Read the guide
Q = Cv√(ΔP ÷ SG)
Valve line size is not valve control size. Use design flow, available pressure drop and operating range to choose a controllable valve.
Read the guide
Expansion ÷ acceptance
The tank must accept the fluid's thermal expansion without allowing system pressure to fall below fill requirements or exceed relief limits.
Read the guide
V = Q × t ÷ (500ΔT)
A buffer tank adds thermal mass when active system volume is too small to give the heat pump or boiler a stable minimum run time.
Read the guide
ρ × cp × flow × ΔT
Glycol provides freeze protection, but copying water-based GPM and head-loss values can undersize flow, pumps and expansion volume.
Read the guide
Q = UAΔT + Qair + Qgains
A practical guide to turning floor-plan geometry, envelope data, weather, people and outdoor air into reviewable room-level HVAC loads.
Read the guide
CFM • V • f • ΔP
Understand what a duct sizer is actually solving—and how to review a system after the first automatic size is selected.
Read the guide
WSFU → demand → pipe size
Use NPC 2020 water-supply fixture units to organize cold- and hot-water demand, developed length, pressure checks and pipe selection.
Read the guide
BTU/h → GPM → diameter
A practical explanation of the load-to-flow calculation and the hydraulic checks that turn GPM into a reviewable pipe size.
Read the guideUse MEPFlow to trace a floor plan, connect systems, calculate results and keep design assumptions visible for review.
Try MEPFlow free