Set room fresh air from CIBSE Guide A or Guide B2. See what it adds to the heating and cooling load, then hand the room schedule to the next designer with the rate and its source attached.

7-day free trial. No card required.

Office rooms traced on a MEPFlow floor plan with heating and cooling demand displayed in each room
Room heating and cooling results on the project floor plan.

Which ventilation basis does your brief specify?

2015, Table 1.5

Guide A · Room type

Select one of 62 supported room types, from open-plan offices to lecture halls. Enter the design occupancy to calculate fresh air in L/s. Each room retains the table reference and source page.

Choose a Guide A room type

2016, Table 2.4

Guide B2 · Air quality

Choose the indoor air quality category specified in the brief. MEPFlow applies the selected IDA people rate for low-pollution spaces with clean outdoor air. The B2 office option is available separately.

Compare Guide B2 categories

2019, Ventilation Rate Procedure

ASHRAE 62.1 · Space use

Use the people and floor-area components for the selected occupancy category. Projects using ASHRAE keep their own room inputs and distribution-effectiveness settings.

Open the ASHRAE calculator

Worked meeting-room example

Six more chairs add 60 L/s of fresh air.

A fit-out changes a boardroom from 12 seats to 18. With the Guide A boardroom rate of 10 L/s per person, the brief changes the outdoor-air duty even though the floor area and glazing stay the same.

Follow the change through to coil duty
Illustrative room schedule · Guide A, Table 1.5, p. 1-12
BoardroomDesign occupantsOutdoor air
Original brief12120 L/s
Revised layout18180 L/s

Total supply air depends on the thermal duty and air distribution design.

From the room schedule to the design review

Set up the rooms

In Heat Loads, choose the project design basis. Apply the room type or category individually or to a selection of rooms. Each room keeps its own occupant count.

Try the Interactive Loads Demo

Review the air and heat duties

Recalculate the ventilation load when the occupancy changes. Check how outdoor air is conditioned before assigning the supply flow to diffusers and sizing the ductwork.

Explore ductwork design

Issue a traceable calculation

Room reports and PDF, Excel and CSV outputs retain the selected basis. A manually edited rate is identified as a project input. Rooms using different standards retain their own references.

Review calculation methods

Scope for UK and European projects

Use these people rates where the project specification calls for them. Kitchens, specialist extract, clinical ventilation, wet-area criteria and air-change requirements need their own design inputs. Check the requirements for the UK nation or European jurisdiction where the building is located. For a coordinated domestic-water design, the plumbing workflow offers separate BS 8558 and BS EN 806-3 loading-unit methods.

Reference editions: CIBSE Guide A and CIBSE Guide B2.

Bring your room schedule into MEPFlow.

Start with a floor plan and the project occupancy brief. Select a ventilation basis, calculate the room loads and export the assumptions for review.

7-day free trial. No card required.